<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-11-26T13:43:54Z</responseDate><request verb="GetRecord" identifier="oai:wakespace.lib.wfu.edu:10339/112278" metadataPrefix="dim">https://wakespace.lib.wfu.edu/server/oai/request</request><GetRecord><record><header><identifier>oai:wakespace.lib.wfu.edu:10339/112278</identifier><datestamp>2026-09-02T16:08:58Z</datestamp><setSpec>com_10339_14934</setSpec><setSpec>col_10339_38132</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="author" lang="en_US">Coltoff, Emma C</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2026-04-22T08:35:59Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued" lang="en_US">2026</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">https://wakespace.lib.wfu.edu/handle/10339/112278</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en_US">Spine biomechanical testing has evolved a wide variety of innovative methodologies and equipment to better understand in vivo spinal biomechanics. Spinal finite element models have enabled evaluation of implants and surgical treatments that are challenging to characterize experimentally. However, these models are validated by comparison to experimental spinal loading and thus, are only able to represent spine behavior characterized by testing. Traditionally conducted “pure moment” loading treats the load-displacement behavior of a spinal segment or functional spinal units as independent along anatomical planes, leaving physiologically important combinations of loading unrepresented in experimentation and consequently, these models. These simplifications have been historically necessary to accommodate limitations of testing equipment, but new systems enable new possibilities. This thesis presents a combination of studies investigating sources of variability in spinal testing and developing a new test methodology to evaluate multidimensional spinal biomechanical behavior. The first study quantified standard practices and corresponding outcome variation within spinal biomechanical testing. Seven established biomechanical testing laboratories each conducted Flexion-Extension, Lateral Bending, and Axial Rotation pure moment testing on Sawbones synthetic lumbar spinal surrogates through whatever protocol was deemed “standard” for their laboratory. The data from this study highlights how much spinal testing procedures can vary in a small sample of laboratories and suggests key areas for testing standardization. 
The subsequent studies are tied to verification, validation, development, and application of the multidimensional spinal testing methodology. Pure moment characterizations are not sensitive to loading path directionality and their impact on the spine biomechanical response. These studies challenge the multidimensional testing technique and debut a companion visualization method on a combination of cervical and lumbar post-mortem human cadaveric and synthetic specimens. The studies demonstrate multidimensional spinal biomechanics across a mixture of loading techniques, disease states, and testing environments. The work from these studies has been and will continue to be used to refine the testing methodology.
Basic understanding of spine biomechanics, performance of spinal finite element models, and bio-fidelity of spinal surrogates are based on data from pure moment experimental loading and would benefit from new data to improve robustness of their predictions of biomechanical behavior.</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en_US">en</dim:field>
   <dim:field mdschema="dc" element="publisher" lang="en_US">Wake Forest University</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">biomechanics</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">multiplanar</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">orthopaedics</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">robotics</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">spine</dim:field>
   <dim:field mdschema="dc" element="title" lang="en_US">Explorations in Spinal Testing: Impact of Test Protocol on Biomechanical Outcomes and Development of a Multidimensional Biomechanics Characterization Methodology</dim:field>
   <dim:field mdschema="dc" element="type" lang="en_US">Dissertation</dim:field>
   <dim:field mdschema="thesis" element="contributor" qualifier="advisor" lang="en_US">Brown, Philip J</dim:field>
   <dim:field mdschema="thesis" element="contributor" qualifier="committeeMember" lang="en_US">Cadel, Eileen S</dim:field>
   <dim:field mdschema="thesis" element="contributor" qualifier="committeeMember" lang="en_US">Colbrunn, Robb W</dim:field>
   <dim:field mdschema="thesis" element="contributor" qualifier="committeeMember" lang="en_US">Stitzel, Joel D</dim:field>
   <dim:field mdschema="thesis" element="contributor" qualifier="committeeMember" lang="en_US">Wilson, Jonathan L</dim:field>
   <dim:field mdschema="thesis" element="degree" qualifier="discipline" lang="en_US">Biomedical Engineering</dim:field>
   <dim:field mdschema="thesis" element="embargo" qualifier="terms" lang="en_US">2027-04-21</dim:field>
   <dim:field mdschema="thesis" element="embargo" qualifier="liftdate">2027-04-21</dim:field>
   <dim:field mdschema="others" element="access-status">open.access</dim:field>
</dim:dim>
</metadata></record></GetRecord></OAI-PMH>